HVAC SYSTEM (HEATER, VENTILATOR AND A/C) > FRESH/RECIRC Door Actuator
INSTALLATION
CAUTION:
• After installing the grille assembly - ventilation RH, check that the air vent grille of the grille assembly - ventilation RH is inserted correctly into the air vent duct.
• Before handling the airbag system components, refer to “CAUTION” of “General Description” in “AIRBAG SYSTEM”. General Description > CAUTION">
Install each part in the reverse order of removal.
Inspection
HVAC SYSTEM (HEATER, VENTILATOR AND A/C) > FRESH/RECIRC Door ActuatorINSPECTION1. CHECK LINK1. Visually check the operation range of the link, and remove the foreign material if any.2. Operate the FRESH/RECIRC switch to check that the link operates normally.3. If it does not operate normally as t ...
Dtc b2276 acc relay off signal
KEYLESS ACCESS WITH PUSH BUTTON START SYSTEM (DIAGNOSTICS) > Diagnostic Procedure with Diagnostic Trouble Code (DTC)DTC B2276 ACC RELAY OFF SIGNALDTC detecting condition:When input error occurs in accessory relay cut input signal of keyless access CM.Trouble symptom:• The accessory power su ...
Inspection
LIGHTING SYSTEM > Day Time Running ResistorINSPECTION1. Measure the resistance between connector terminals.Preparation tool:Circuit testerTerminal No.Inspection conditionsSpecificationConnection diagram1 — 2Always1.13±0.05 ?2. Replace the resistor assembly - daytime running light if the inspec ...