HVAC SYSTEM (HEATER, VENTILATOR AND A/C) > Relay and Fuse
INSPECTION
1. CHECK FUSE
1. Remove the fuse and inspect visually.
2. If the fuse is blown out, replace the fuse.
NOTE:
If the fuse is blown again, check the system wiring harness.
2. CHECK RELAY
1. Check the resistance between relay terminals.
• A/C relay
Terminal No. | Inspection conditions | Standard | Circuit |
1 — 2 | Always | 1 M? or more |
1 — 2
Apply battery voltage between terminals 4 and 3.
Less than 1 ?
• Blower motor relay
Terminal No. | Inspection conditions | Standard | Circuit |
1 — 4 | Always | 1 M? or more |
1 — 4
Apply battery voltage between terminals 2 and 3.
Less than 1 ?
2. Replace the relay if the inspection result is not within the standard.
Assembly
MANUAL TRANSMISSION AND DIFFERENTIAL(5MT) > Drive Pinion Shaft AssemblyASSEMBLY1. Install the sleeve and the gear and hub assembly by matching the alignment marks.NOTE:• Make sure that there is no large clearance at both sides of the 1st-2nd shifting insert after assembly.(A)1st-2nd shiftin ...
Inspection
HVAC SYSTEM (HEATER, VENTILATOR AND A/C) > Blower Resistor (Manual A/C Model)INSPECTION1. Check the resistance between resistor terminals.Preparation tool:Circuit testerTerminal No.StandardConnection diagram4 — 3Approx. 0.43 ?4 — 2Approx. 1.03 ?4 — 1Approx. 3 ?2. Replace the resistor if the ...
Dtc b16f6 curtain airbag sensor rh recognition error
AIRBAG SYSTEM (DIAGNOSTICS) > Diagnostic Chart with Trouble CodeDTC B16F6 CURTAIN AIRBAG SENSOR RH RECOGNITION ERRORDiagnosis start condition:Ignition voltage is 10 V to 16 V.DTC detecting condition:• Curtain airbag sensor RH is misinstalled.• Airbag CM is faulty.CAUTION:Before perfor ...