Subaru Crosstrek manuals

Subaru Crosstrek Service Manual: Inspection

SECURITY AND LOCKS > Access Key

INSPECTION

1. ACCESS KEY BATTERY

Check the access key battery voltage.

Preparation tool:

Circuit tester

NOTE:

Complete the measurement within 5 seconds because the battery discharges during measurement.

Battery terminal

Inspection conditions

Standard

(+) — (−)

Connect resistor (A) 47 ?

2.5 — 3.0 V

Replace the battery if the inspection result is not within the standard value. (Use CR2032V or equivalent.)

Access key
...

Replacement
SECURITY AND LOCKS > Access KeyREPLACEMENT1. ACCESS KEY REGISTRATIONNOTE:• A maximum of seven access keys can be registered for each individual vehicle.• When replacing or adding an acc ...

Other materials:

Dtc b16f2 front sub sensor rh recognition error
AIRBAG SYSTEM (DIAGNOSTICS) > Diagnostic Chart with Trouble CodeDTC B16F2 FRONT SUB SENSOR RH RECOGNITION ERRORDiagnosis start condition:Ignition voltage is 10 V to 16 V.DTC detecting condition:Front sub sensor (RH) is misinstalled.CAUTION:Before performing diagnosis, refer to “CAUTION&rdqu ...

Inspection
LIGHTING SYSTEM > Combination Switch (Light)INSPECTIONMeasure the resistance between connector terminals. If it is not within the standard value, replace the switch assembly - combination turn dimmer.Preparation tool:Circuit tester1. LIGHTING SWITCHTerminal No.Inspection conditionsStandard18 — ...

Service diagnostics mode Operation
ENTERTAINMENT > Service Diagnostics ModeOPERATIONNOTE:Installed only to model with 7 inch display.1. PROCEDURE TO SWITCH TO SERVICE DIAGNOSTICS MODE1. Turn the ignition switch to ACC.2. After turning the ignition switch to ACC and wait for 20 seconds or more, press the button (b) five times with ...