LIGHTING SYSTEM > SRF OFF Switch
INSPECTION
1. Measure the resistance between connector terminals.
Preparation tool:
Circuit tester
Terminal No. | Inspection conditions | Standard |
2 — 3 | OFF | 1 M? or more |
ON | Less than 1 ? |
2. Apply battery voltage between the connector terminals to check lighting condition of illumination inside the switch.
Terminal No. | Inspection conditions | Specification |
1 (+) — 4 (−) | Apply battery voltage. | Light ON |
3. Replace the SRF OFF switch if the inspection result is not within the standard value.
Installation
POWER ASSISTED SYSTEM (POWER STEERING) > Universal JointINSTALLATION1. Before installation, check the universal joint assembly - steering. Universal Joint > INSPECTION">2. Adjust the tilt position of the column assembly - steering to the neutral position and lock the tilt lever.3. Ali ...
Subaru select monitor Operation
HVAC SYSTEM (AUTO A/C) (DIAGNOSTICS) > Subaru Select MonitorOPERATIONFor detailed operation procedures, refer to “Application help”.NOTE:When initialization communication using Select Monitor is impossible, perform diagnosis according to “Diagnostic Procedure Used When Abnormal ...
Dtc u0424 invalid data received from hvac control module
CONTINUOUSLY VARIABLE TRANSMISSION (DIAGNOSTICS) > Diagnostic Procedure with Diagnostic Trouble Code (DTC)DTC U0424 INVALID DATA RECEIVED FROM HVAC CONTROL MODULENOTE:Refer to “LAN SYSTEM (DIAGNOSTICS)” for diagnostic procedure. Basic Diagnostic Procedure">1. OUTLINE OF DIAGN ...