Subaru Crosstrek Service Manual: Dtc b1675 satellite safing sensor failure

AIRBAG SYSTEM (DIAGNOSTICS) > Diagnostic Chart with Trouble Code

DTC B1675 SATELLITE SAFING SENSOR FAILURE

Diagnosis start condition:

Ignition voltage is 10 V to 16 V.

DTC detecting condition:

Satellite safing sensor is faulty.

Airbag control module is faulty.

CAUTION:

Before performing diagnosis, refer to “CAUTION” in “General Description”. General Description > CAUTION">

STEPCHECKYESNO

1.REPLACE SATELLITE SAFING SENSOR.

1) Turn the ignition switch to OFF, disconnect the battery ground cable, and wait for 60 seconds or more.

2) Replace the satellite safing sensor with a genuine sensor. Satellite Safing Sensor > REMOVAL">

Does the warning light go off?

Finish the diagnosis.

Replace the airbag control module. Airbag Control Module > REMOVAL">

Dtc b1660 passenger s airbag on indicator failure
AIRBAG SYSTEM (DIAGNOSTICS) > Diagnostic Chart with Trouble CodeDTC B1660 PASSENGER’S AIRBAG ON INDICATOR FAILUREDiagnosis start condition:Ignition voltage is 10 V to 16 V.DTC detecting condi ...

Dtc b1676 lost communication with satellite safing sensor
AIRBAG SYSTEM (DIAGNOSTICS) > Diagnostic Chart with Trouble CodeDTC B1676 LOST COMMUNICATION WITH SATELLITE SAFING SENSORNOTE:For details on DTC B1676, refer to DTC B1677. Diagnostic Chart with Tr ...

Other materials:

Dtc p1497 coil 3 egr "a" control circuit high
ENGINE (DIAGNOSTICS)(H4DO) > Diagnostic Procedure with Diagnostic Trouble Code (DTC)DTC P1497 COIL 3 EGR "A" CONTROL CIRCUIT HIGHNOTE:For the diagnostic procedure, refer to DTC P1499. Diagnostic Procedure with Diagnostic Trouble Code (DTC) > DTC P1499 COIL 4 EGR "A" CONTRO ...

Removal
ENTERTAINMENT > GPS AntennaREMOVALCAUTION:Before handling the airbag system components, always refer to “CAUTION” of “General Description” in “AIRBAG SYSTEM”.1. Disconnect the ground cable from battery and wait for at least 60 seconds before starting work. NOT ...

Disassembly
INSTRUMENTATION/DRIVER INFO > Combination MeterDISASSEMBLYCAUTION:• Use gloves to avoid damage and getting fingerprints on the glass surface and meter surfaces.• Be careful not to apply excessive force to the trip knob.• Be sure not to touch the meter indicator needle.• Be ...

© 2016-2024 Copyright www.sucross.com