CONTINUOUSLY VARIABLE TRANSMISSION(TR580) > Converter Case
ASSEMBLY
1. Install the oil drain plug.
Tightening torque:
70 N·m (7.1 kgf-m, 51.6 ft-lb)
2. Install the overflow drain plug.
NOTE:
Overflow plug of differential gear oil is temporarily attached.
3. Install all plugs.
NOTE:
Use new O-rings.
Tightening torque:
T1: 22 N·m (2.2 kgf-m, 16.2 ft-lb)
T2: 22.5 N·m (2.3 kgf-m, 16.6 ft-lb)
4. Install the pitching stopper bracket and transmission radio ground cord.
CAUTION:
Be careful not to deform or damage the terminal of transmission radio ground cord.
Tightening torque:
41 N·m (4.2 kgf-m, 30.2 ft-lb)
Inspection
HVAC SYSTEM (HEATER, VENTILATOR AND A/C) > Blower Resistor (Manual A/C Model)INSPECTION1. Check the resistance between resistor terminals.Preparation tool:Circuit testerTerminal No.StandardConnection diagram4 — 3Approx. 0.43 ?4 — 2Approx. 1.03 ?4 — 1Approx. 3 ?2. Replace the resistor if the ...
Inspection
HVAC SYSTEM (HEATER, VENTILATOR AND A/C) > Ambient SensorINSPECTION1. Visually check the ambient sensor for dirt or damage, and clean or replace as necessary.2. Check the resistance between ambient sensor terminals.CAUTION:During inspection, be careful not to touch the sensor end in order to avoi ...
Access key - if access key does not operate properly
CAUTION
Keep metallic objects, magnetic
sources and signal transmitters
away from the area between the
access key and the push-button
ignition switch. They may interfere
with the communication between
the access key and the push-button
ignition switch.
The following functions may be inopera ...